China Telecom: South Sichuan Campus

Latest Podcast
No. 16
OperationalPlanned
Operational with future phases planned
Operated by:

China Telecom: South Sichuan Campus

Year Built: 2020
PUE: 1.4
Floors: 4
Lot Size: 112 acres
░░░░░░░ Login to view SqFt
Total Building Size
░░░ Request Dataset MW
Total Power

South Sichuan Data Center is located at Lingang Economic Development Zone, Yibin, Sichuan. The overall planning of the data center park has a service capacity of 10,000 cabinets, with a total broadband access of 5T-10T. The park covers an area of 112 acres. The construction area is about 200,000 square meters, with 1,250 cabinet service capabilities and 1T bandwidth support for the telecom backbone network. The data center complies with the China GB50174-2018 Class A construction standard and conforms to the international Tier 3+ standard.

Features


  • Total broadband capacity of 5T-10T, 1T bandwidth support for the telecom backbone network.
  • Energy-saving and environmental protection technology to create a “green & low carbon” data center with cold aisle enclosed technology
  • Phase 1 is a framed 4-story single-floor data hall with a construction area of 12,000 square meters. The date center has a structural safety level of Class I and a degree of 7-degree earthquakeresistant measures; the frame has a Class II seismic rating. The floor bearing capacity of the Data Center is 1000KG/m², and the floor load of the power battery room is 1600KG/m².
  • Multiple power guarantees, including power supply for critical equipment adopts a 2N+ backup power supply system
  • UPS system that adopts 2N configuration, a total of 24 600KVA UPS and four 200KVA UPS, while the backup battery for the UPS system supplies power continuously for more than 30 minutes.
  • IG541 gas fire-fighting and pre-installed Heptafluoropropane fire-extinguishing system. Complies with the “Code for Fire Protection Design of Buildings” (GB50016-2006 and later versions)
  • Chilled water precision air conditioner that ensures the computer room stays at a constant temperature of 18-27 degrees Celsius and helps meet 30% to 70% constant humidity environment requirements
  • Air-conditioning terminal equipment using UPS plus main dual-circuit power supply, for a total of 1 400KVA UPS and three 200KVA UPSs.

Map and Nearby Locations:

No. 16
China Telecom Sites
Nearby Facilities

China Telecom: South Sichuan Campus Data Center Photos (See all)

Operating Company

Operated by:

China Telecom Americas is headquarted in Herndon, Virginia with offices in Chicago, Dallas, Los Angeles, Miami, New York and San Jose, a subsidiary in Toronto, Canada.

23
Facilities
2
Markets
484MW
Megawatts

News (See all)

Read More News

Podcasts (See all)

See More Podcasts

Documents (See all)

Ready to Level up Your
Data Center Strategy?